Your
information is protected with multi layered security:
Data Security:
The SSL (secure sockets layer) protocol
is the Web standard for encrypting communications
between users and e-commerce sites. Data sent
via an SSL connection is protected by encryption,
a mechanism that prevents eavesdropping and tampering
with any transmitted data. SSL provides businesses
and consumers with the confidence that private
data sent to a Web site, are kept confidential.
Customers know when they have an SSL session with
a website when their browser displays the little
gold padlock and the address bar begins with a
https rather than http.
Companies that issue SSL certificates are in the
business of establishing that entities on the
Web are, in fact, who they claim to be. Rapid
SSL ensures that www.WebTCards.com is, in fact,
WebTCards Ltd. In the “real world”,
using identification procedures like photo ids,
telephone calls and papers of incorporation.
|
| |
Access Security:
• Login
• Encrypted password
• Password change
• User profiles |
| |
Physical Security:
General Information on (UK) Data Centre Facility |
| |
Facility
• Building: Steel frame with in-situ concrete slabs
• Site: The ground floor rated to 50KN/m2. The first floor rated to 12KN/m2
• Height: 3000mm clear between the raised floor and the lower ceiling
• Floor: Anti-static 600mmx600mm steel tiles with a 4.5 kN point load capacity (0.01 ohm per centimetre) and 750mm heavy duty raised floor system
• Fibre entry: Preinstalled 54 (110mm) ducts from three elevations
• Cabling: Copper, UTP and fibre managed via pre-cabling system to rack via DDF and ODF |
| |
Security
• ISO9001:2000 secure access procedure.
• Three stage access to site - entry door, mantrap and reception - with three levels of security.
• Bandit glass mantrap and air lock. Full height in and out turnstiles.
• 24/7 manned security guards
• 24/7 monitoring, photo ID access cards
• Biometric verification scanners
• Digital CCTV with minimum of 31 days of digitally recorded material
• Monitored perimeter doors
• Anti-pass back system
• Intruder alarm, Equipment alarm |
| |
Environment
• Temperature set point: 22 +/- 2C
• Redundancy: N+1 configuration
• Cooling Capacity: 1KW/m
• Humidity set point: 48% +/- 15% |
| |
Power
• Power feed: 24MVA fully rated diverse supplies
• Power on site: 230V AC or 400V three-phase AC
• Generators: N+1 configuration - 24MVA generator with maximum 20 second on load time
• 36 hour on site fuel autonomy
• Refuelable during use and 240 minutes fuel delivery callout contract in place on 24/7 basis
• Batteries: N+1 configuratoi - 12MVA - 10 minutes autonomy
• Grounding system: TNCS
• Lighting: High frequency, low energy, CAT II luminaries |
| |
Fire suppression
• Two stage fire detection
• Aspiration system: Multiple zoned system utilizing forward light scattering analysis
• Point detection: Addressable Analogue point detection system using a combination of optical and ionization detectors operating a double knock protocol
• Suppression: Nitrogen propelled system. Independent 5m zoned system ensuring localised control. No evacuation required and no effect on electrical equipment. |
| |